Press Releases from CAS DataLoggers (428 total)
Vibration Monitoring and Control in a Single System
Delphin Expert Vibro for Data Acquisition and Test Stand Automation
Do you need to monitor vibration or to automate a test stand? Does your existing system need to be replaced? The Delphin Expert Vibro Data Acquisition and Control System offers much more than its competitor models while also having a wider range of applications. This flexible and versatile system is popular with Engineers and technicians around the world as a way…
Versatile Datalogger Captures Data for Device Validation
Log it All with dataTaker!
Whether startups or large manufacturers, companies have come to rely on data capture for device validation and proof of scale for prototype devices. dataTaker Universal data loggers can capture almost any measurement value, making them ideal for performance monitoring and device component monitoring. These versatile loggers enable connection to many different sensor types. Whether you need to record electrical, environmental, or weather data, dataTaker will log…
New Waterproof Power and Energy Logger is Easy to Use
PEL 105 Power and Energy Loggers from AEMC
Do you need a waterproof device to record power and energy? Now CAS DataLoggers offers the flexible new PEL 105 Power and Energy Data Logger from AEMC. This new data logger is ideal for electricians, engineers and contractors working in building/system monitoring and upgrades, as well as residential energy audits. These cost-effective products have high speed and a removable SD memory to suit…
Simple, Flexible Data Acquisition in the Lab
Delphin Expert Key Monitors & Controls Lab Processes
In lab settings, measurement technology needs to be both flexible and simple to operate. The Expert Key Data Acquisition System from Delphin is especially suited for labs in the chemical and pharmaceutical sectors as well as in universities. Any type of sensor can be used with the Expert Key. Data from laboratory equipment can also be acquired via serial interfaces. Additionally, Delphin’s ProfiSignal…
New Real-Time Monitoring App Gives You Peace of Mind
New App from dataTaker Displays Data on Your Mobile Device
Do you need to keep tabs on your product or process when you’re away from work or outside of business hours? Now dataTaker introduces the new dEX Tablet Apps for iOS and Android, making it easy to remotely manage your datalogger network. The new app is now available on Google Play and the App Store.
Versatile products with an intuitive user…
Cleanroom Monitoring Systems Keep Pharma Data Secure
Delphin Technology Offers Secure Data Acquisition
Continuous and secure data acquisition and documentation is especially important in the pharmaceutical industry for its unique production and storage requirements, as well as for proprietary research and development. According to FDA Part 11, data acquisition and monitoring systems in cleanrooms must operate in compliance with GAMP/GMP guidelines.
For effective monitoring, measurement data and limit values for parameters such as Temperature, Humidity, Particle count and…
Detecting DC Motor Failure Using a Data Logger
DC motor failure is disastrous for factories and plant processes in every industry. To help prevent costly process delays, you can use a data logger to measure Temperature, Voltage/Current and other parameters. At CAS DataLoggers we provide the versatile and rugged dataTaker data loggers for these applications. Call our Application Specialists at (800) 956-4437 for more info.
DataTaker Features:
The dataTaker DT82E was designed to handle continual monitoring applications where robust functionality…
High-Speed Recording of Frequency Trigger Points
ADwin Systems Log Data at Speeds of 25 Nanoseconds
At CAS DataLoggers we occasionally have customers in the power generation industry whose application involves a quickly-fluctuating waveform. These technicians need to accurately determine the frequency of a given waveform at each of its cycles. This can occur when manufacturers and servicers need to ensure the stability and reliability of their generators. For these applications, we offer real-time ADwin-Light Data Acquisition Systems…
CAS Dataloggers Makes It Easy to Find the Right Solution
Need to log data for regulatory requirements, product safety or another reason? CAS Dataloggers offers data loggers to record and log nearly ANY measurement type including Temperature, Humidity, Voltage/Current and more. We also provide pre- and post-sales support. Find the ideal device for your application by searching for Dataloggers by Measurement Type on our website, or call us today at 1-800-956-4437.
Temperature Data Loggers
CAS DataLoggers carries Temperature data loggers from over…
Time-Synchronized Acquisition of GPS Positional Data
A Single System for Measurement and Analysis
Delphin data loggers have the ability to determine positions via GPS signals. This is ideal for vehicular applications including automotive testing, flight testing, field trials and more. The GPS signal is received via a GPS sensor serially connected to a Delphin data logger. The sensor records GPS data according to the NEMA protocol. The Delphin device can then compute (independently and online), positional determination…
Tracking Environmental Conditions of Livestock Barns
Data Loggers Let Producers Check Animal Health from Mobile Devices
Keeping livestock healthy is of the utmost importance for meat and dairy producers. Their barns hold hundreds of cows, pigs and other animals producing meat, milk and eggs. Excessive heat and humidity are one of the largest risks to livestock health, causing heat stress and loss of appetite. However, many suppliers are turning to technological advances (already in use in cold…
What Are Solid-State Temperature Sensors?
Monitor Your Product or Process Reliably
Temperature measurements are among the most common data logging applications found across a broad variety of industries including cold chain integrity, medical monitoring, machine/equipment monitoring, environmental monitoring, and in practically every other field. Since temperature monitoring devices are designed for such a wide variety of needs, it’s important that you decide on the type of sensors or inputs you’ll use. However it can seem like…
Delphin Offers Extensive Driver Development
Let Delphin Develop Your Application!
For flexible use in many different measurement applications, communication between Delphin data loggers and third-party ICA technology is possible using standard protocols. The communication interfaces in Delphin ProfiSignal software and hardware provide a multitude of options for exchanging data. CAS DataLoggers distributes Delphin dataloggers in the US--just contact us at 1-800-956-4437 if you have questions about connecting an ICA system to Delphin hardware or software.
…
Need Temperature Monitoring for a Fridge or Freezer?
CAS DataLoggers Has Your Solution!
If you need temperature monitoring for a refrigerator or freezer, a Temperature Datalogger is an ideal way to get peace of mind. Whether you’re storing food product in a deli freezer or vaccines in a medical storage unit, data loggers help you to protect your product with alarms while also documenting temperature history for regulations and inspections.
CAS DataLoggers carries temperature data loggers from over 16 manufacturers…
Fast and Flexible Technology for Test Measurement
Professional Test and Measurement Systems
Heating unit and HVAC system testing is performed according to a wide range of industrial standards. Measurement data provides the basis for a product‘s technical specifications, so a manufacturer’s sensor technology has to be capable of high-level precision. Meanwhile technicians require full automation of testing procedures and test results, but implementing this involves lots of effort and is error-prone. However, users can easily generate the complex…
Data Loggers for Harsh Industrial Environments
Find Class 1 Division 2 Data Loggers and Custom Enclosures
Explosions, fires and corrosion pose ever-present dangers to electrical instrumentation operating in heavy industrial environments. OSHA and other organizations classify work areas according to the presence of flammable materials or gases. For data capture in Oil & Gas, Chemical, and other processing applications, users require specially-protected data loggers
At CAS DataLoggers we have provided a number of solutions for data logging in…
Measuring Bearing Vibration Levels
Data Acquisition Systems for Fault Diagnosis & Condition Monitoring
The diagnosis of bearing damage in roller bearings is an integral part of servicing and maintenance tasks. Increasingly, technicians rely on condition monitoring systems (CMS) for machine diagnoses in plants and factories. Many CMS systems are based on vibration measurements. Two contrasting approaches exist: the diagnostic, qualitative approach (producing an envelope spectrum); and the quantitative approach (measuring vibration velocity).
Delphin Expert Vibro…
New Paperless Chart Recorder with 12.1" Touchscreen Display
Keep an Eye on Your Data with the Brainchild PR-30
Need to keep tabs on Temperature or another value in your process or experiment? CAS DataLoggers and Brainchild jointly introduce the all-new Brainchild PR-30, an advanced paperless chart recorder with a built-in high-resolution 12.1" touchscreen display and up to 48 channels. Suited for process monitoring with a real-time display for high channel-count applications, these portable models are now available from at…
Automated Temperature Monitoring Helps Save Vaccines
CAS DataLoggers Offers World-Class Medical Monitoring
According to Medical Lab Management Magazine, half of all hospital labs have installed automated temperature monitoring devices to help protect their critical vaccines and healthcare supplies. Another 20% of these labs say that they plan to source a system over the next few years. To help protect your lab’s vaccines and life science products, CAS DataLoggers offers temperature monitoring systems to match any budget or…
Delphin Upgrades ProfiSignal Measurement Software
Version 4.2.10 Available for Download at CAS DataLoggers
CAS DataLoggers and Delphin Technology are proud to announce the release of an improved version of Delphin’s popular ProfiSignal data acquisition software. Version 4.2.10 adds new bug fixes as suggested by users around the world. You can download the new version from our Delphin Downloads page at http://www.dataloggerinc.com/downloads/delphin.php. Whether you work in test, process control or another application, at CAS DataLoggers we can…
Real-Time Control System Automates Paleomagnetic Studies
ADwin DSP Enables Precise Switching of Magnetic Fields
Paleomagnetic research studies the magnetic history of geology as embodied in rock samples. These samples of interest contain metallic traces still oriented to the earth’s magnetic field as it existed at the time of the rock’s formation. To save time spent taking manual measurements, laboratory researchers are using automated control systems for precise real-time control. CAS DataLoggers supplies researchers in this field with…
Accsense Electrocorder Offers Discount on Energy Data Loggers
Save 15% off Select Models!
Starting today, CAS DataLoggers is offering a 15% discount on select models in its line of Accsense Electrocorder dataloggers! These electrical logging devices monitor power/energy, current/voltage, power factor and more. Our Application Engineers are available with more details—just call 1-800-956-4437!
The Accsense Advantage:
Accsense Electrocorder products use a constant sampling technique, unlike the single ‘snapshot’ reading of competing devices. When these data loggers start to record, they…
Accsense Versalog Releases New Software Version
Versatile 8-Channel Data Loggers for Many Applications
CAS DataLoggers is pleased to announce a new software upgrade for Accsense VersaLog dataloggers. Released in July, SiteView 3.1.1 extends functionality while adding various bug fixes. Accsense VersaLog products are ideal to capture and record your crucial data. If you need a cost-effect device to collect data and for local alarming, call CAS DataLoggers today at (800) 956-4437!
Powerful Software:
SiteView is a PC-based application…
Precision Electrical Measurement Using Delphin
Fully-Automated Engine Test Stands
Motor Test stands are required during the automotive R&D phase for serial testing and also for endurance trials. Measurements taken during the developmental phase such as Temperature and Voltage are fully-automated whenever possible. Sensors check the electrical and mechanical properties of the test sample as well as temperature patterns and overload operation. Testing conditions can vary widely--from the tiniest of motors to large drives in the megawatt…
Optimize Your Batch Oven Process with Temperature Profiling
Increase Profitability and Part Quality!
Whether you’re preheating, drying or curing a part, oven temperature data is integral to operation audits for batch ovens and other types of process oven applications. Looking at your performance, you can see if your batch oven’s temperature really is uniform, or if in fact there are ‘hot’ and ‘cold’ spots inside which can ruin consistency.
Using the Grant Oven Temperature Profiling Kit, you can obtain…
Securing the dataTaker DT80 Series Web Services
Series 3 dataTaker Universal DataLoggers
Series 3 dataTaker dataloggers are popular for their communications functionality and for their ease of programming using the built-in dEX software. In our latest Technical Article, CAS DataLoggers shows you how to assign password protection to your dataTaker DT80 series logger and how to limit access to its interface if desired.
1. Setting Changes (in dEX Software)
NOTE: The changes specified in this document require your logger to…
Influx Rebel CT for CAN-Based Vehicle Recording
All-in-One Dataloggers Record Right out of the Box!
CAS DataLoggers offers the Influx Rebel CT vehicle datalogger, a new all-in-one vehicle datalogger for CAN vehicular data collection applications. Now users can capture real-time data including Temperature, RPM, Brake and Throttle settings, Latitude/Longitude, Speed, and more. Rebel CT loggers record vehicle network and sensor data for extended periods without any user interaction. Call our Applications Specialists at (800) 956-4437 today!
Influx Rebel series…
Record Current and Voltage with Accsense Electrocorder
DC-3VA Two-Channel DC Voltage and Current Logger
Do you need a device to record current and voltage data for machine monitoring, circuitry test, battery charging/discharging, or another application? CAS DataLoggers offers the affordable Accsense Electrocorder DC-3VA Voltage and Current Data Logger Kit which records electrical data on 2 channels at fast sample rates and high accuracy.
With its large memory, the DC-3VA is ideal for use in low-voltage and current applications.…
High-Speed Acquisition of Velocities
Delphin Data Loggers for Test and Simulation Applications
Pumps are required in diverse applications ranging from micro-dosage pumps in chemistry labs, standard pumps for gardens, all the way through to large-scale industrial or vacuum pumps. Each application has different test requirements, so users working in the pump sector greatly benefit from the flexibility and universal inputs of the Delphin Message and Expert Key devices.
Adjustable sampling rates of up to…
Delphin Systems Provide SDI-12 Sensor Integration
Versatile Data Logger Connects to Enviro Smart Sensors
The SDI-12 interface (Serial Data Interface at 1200 Baud) enables, via a digital signal, the establishment of a connection with multiple "low-power" sensors and a data logger. Sensors can be operated on the bus with asynchronous, serial communication protocols. Such sensors (e.g. for soil moisture, soil temperature, air humidity, water potential, electrical conductivity, etc.) are primarily used in environmental engineering.
Now users can…
Flexible Measurement System for Test & Lab Applications
New Delphin Expert Logger 400 is Versatile, Reliable
The new Expert Logger 400 from Delphin combines the latest communication capability with advanced measurement technology. Designed to fulfil many applications including data logging, product test, lab data acquisition, process monitoring and more, this compact system offers simple operation. The new 400 model can process up to 16 universal analog input channels at high sampling rates up to 1000 Hz.
Now measurement data…
Data Loggers for HVAC Performance Validation
Fully-Automated Recording of Temperature & Humidity
Are you working in an HVAC application such as temperature monitoring in vents and ducts, humidity recording in greenhouses, or logging carbon dioxide levels in schools? Data loggers are an affordable way to automate environmental data collection for HVAC system validation. Compact and highly accurate, they’re ideal for monitoring indoor air quality and also for recording pressure, events, and more. CAS DataLoggers offers products from…
Intelligent Data Logging Using an ADwin
Data Logging with Real-Time Pre-Processing of Data
ADwin Real-Time systems are ideal for intelligent data acquisition and control applications. Utilizing the programmability of the local CPU in the ADwin, users can run real-time datalogging and/or control programs with kHz execution speeds up to the MHz range. CAS DataLoggers offers these systems along with technical support-- contact a CAS Data Logger Applications Specialist at (800) 956-4437 or visit our website at www.DataLoggerInc.com.
ADwin’s…
Measuring Depth Using a dataTaker data logger and a Druck Depth/Level Sensor
Using Druck PTX 1830 Series Sensors
CHESTERLAND, OH—June 23, 2016
In this Tech Article from CAS DataLoggers and dataTaker, we describe the process of connecting the Druck PTX 1830 depth/level sensor to a dataTaker DT8x series data logger. This sensor outputs a 4-20mA signal and will be powered by the dataTaker’s switchable 12V regulated voltage output.
1. Equipment required:
•dataTaker DT8x data logger
• Druck PTX 1830 depth sensor
•Wire
2. Connecting the sensor:
Connect the…
Jager-ADwin Releases New Software Update
Ver. 6.00.08.01 Adds Support for MATLAB, LabVIEW
CHESTERLAND, OH—June 20, 2016
Jager-ADwin has just released a new version of the ADwin CD-ROM. Version 6.00.08.01 adds more support for MATLAB and LabVIEW, improved cache management, and several minor bugfixes. ADwin data acquisition and control systems are ideal for applications in automotive test, laboratory data acquisition, product R&D and more. The new ADwin CD-ROM is ready for download at CAS DataLoggers on our ADwin…
Vaccine Safety—What’s it Worth to You?
Accsense Medical Monitoring is the Gold Standard
CHESTERLAND, OH—June 6, 2016
The federal Vaccines for Children (VFC) program requires that providers must follow CDC vaccine storage and handling guidelines. However, the data loggers used in VFC programs are literally the cheapest devices that money can buy. Given that most VFC refrigerators contain vaccines valued at $30,000 to $60,000, how much is vaccine safety worth to you?
For regulatory compliance in clinics and…
Wireless Dataloggers Ensure Accuracy in a Calibration House
Users Pull Environmental Data with a Button Press
CHESTERLAND, OH—May 31, 2016
CAS DataLoggers recently provided the datalogging solution for Total Calibration Solutions Inc., an Ohio-based calibration house for test and measurement instruments throughout North America. As an ISO/IEC 17025:2005 and ANSI/NCSL Z540-1-1994-accredited calibrator, Total Calibration is using the loggers not only to log and verify sensor calibration for their customers, but also to help customers with specific applications including monitoring a…
Lascar Introduces EasyLog-21-CFR Software
21-CFR-Compliant Data Logging
CHESTERLAND, OH—May 23, 2016
Do your temperature monitoring systems need to be 21-CFR Part 11-compliant? Lascar now offers all the software security demanded by this regulation, along with a combination temperature and humidity logger. The software is compatible with Lascar’s EL-21CFR-2-LCD Temperature, Humidity and Dew Point Datalogger. CAS DataLoggers supplies this and other Lascar dataloggers for users in Food & Beverage, Life Science and more—call us today at…
Wireless Dataloggers Manage Temp & Humidity in Greenhouses
Compact and Rugged Dataloggers from T&D
CHESTERLAND, OH—May 9, 2016
Effective environmental monitoring in greenhouses requires devices with remote monitoring capability so users get immediate alarms anytime, anywhere. T&D wireless data loggers can easily be placed anywhere in a greenhouse or hothouse in order to track temperature and humidity. The T&D Handheld Data Collector can then be used to collect necessary data when needed without ever having to travel to the data…
Go Wireless with Accsense Monitoring Systems!
Accsense A1-01a Wireless Environmental Monitor
CHESTERLAND, OH—May 4, 2016
If you need a device to monitor your product or environment, a wireless system is usually the easiest way to go. Accsense Monitoring systems are commonly used for temperature and humidity monitoring in hospitals and pharmacies, for environmental monitoring in industry and medical cleanrooms, cold chain storage, and in many other industries. Accsense can protect your business from losing inventory, experiencing process…
VersaLog Products Log Data on 8 Channels
Affordable Data Loggers with Alarm Capability
CHESTERLAND, OH—May 3, 2016
If you need to record data on several channels but don’t want to pay extra for features you don’t need, CAS DataLoggers offers its affordable Accsense VersaLog dataloggers which log on 7-8 channels each. These low-cost solutions are perfect for datalogging applications which also require a local alarm notification. Our standalone recorders can log Temperature, Humidity, Current/Voltage and more. Accsense VersaLog is…
Using a dataTaker DT80 with BrainChild IO-16DI Modules
Digital I/Os for Use with HMI, PLC or SCADA via Modbus RTU
CHESTERLAND, OH—May 2, 2016
In our latest Technical Article adapted from dataTaker, CAS DataLoggers shows you how to use a dataTaker DT80 Intelligent Datalogger with a Brainchild Digital IO-16DI Module. This is useful for adding extra inputs for applications involving monitoring or controlling a PLC or SCADA system via the Modbus RTU protocol. The process involves connecting the I/O…
Log HVAC and Environmental Data Using Bluetooth!
Record Temp and Humidity with One Compact Device
CHESTERLAND, OH—April 28, 2016
Do you need a device for HVAC performance verification or to record environmental data? Now Lascar offers you a way to collect the data using Bluetooth with the new EL-BT-2 Bluetooth Wireless Temperature and Humidity Datalogger. This compact and inexpensive product shows its measured Temperature and Humidity readings on its LCD screen, while you can also use Lascar’s new Android…
LogMessage Series for Stand-Alone Monitoring
Single System Measures Nearly Any Sensor Type!
CHESTERLAND, OH—April 27, 2016
Delphin's LogMessage hardware series offers data loggers for virtually any area of application. These devices are capable of acquiring practically any type of sensor signal such as Voltages, Currents, Temperatures, Pressures or Levels. Digital signal acquisition is also possible such as from meters or switches. Measurement rates range from millisecond to hourly intervals. At CAS DataLoggers we distribute Delphin products in…
T&D Discontinues TR-81 Units
CAS DataLoggers Offers Next-Gen T&D Wireless & Wired Loggers
CHESTERLAND, OH—April 26, 2016
T&D Corporation has announced that they are discontinuing the TR-81 Wide-Range Temperature Datalogger. This announcement comes as T&D increases support for their next-generation TR-7wf Wireless LAN series of temperature and humidity loggers. CAS DataLoggers provides T&D’s newest Wireless and Wired Data Loggers for Food & Beverage, Storage/Transit and Lab applications. Call our Applications Engineers at (800) 956-4437 today and…
How to Collect Energy Data Compliant to EN50001
Using a Data Logger to Collect and Analyze Current and Voltage Data
CHESTERLAND, OH—April 25, 2016
The EN50001 standard requires high energy-consuming industries to implement energy-saving measures and, when required, to install energy management systems. Energy consumption data therefore requires users to record data, which can be performed using Delphin Message series dataloggers. Due to their LAN interfaces, these devices can be located throughout a facility and installed directly at the plant…
CAS DataLoggers Is in Puerto Rico for CSIA 2016!
Demonstrating the Latest Measurement & Control Technology
CHESTERLAND, OH—April 21, 2016
Right now CAS DataLoggers Sales Manager Pete Martin is in Puerto Rico exhibiting at CSIA 2016, a gathering of systems integrators seeking the latest monitoring & control systems. The annual Control System Integrators Association Executive Conference provides attendees with an unequalled opportunity to meet with over 60 companies representing every industry. Use this professional measurement technology for your own application--call a…
Modbus Networking in a Hospital
Monitoring Freezers for Temperature of Vaccines
CHESTERLAND, OH—April 20, 2016
Recently a hospital required an automated temperature monitoring solution in order to measure and record the temperature of 50 freezers storing temperature-sensitive life science products. These freezers are located throughout the facility on 3 separate floors, but users need centralized access to all the temperature data.
The hospital’s IT department also had a key requirement that they should be able to monitor…
ADwin for CAN-FD Automotive Applications
CAN-FD Standard Enables Higher Data Throughput
CHESTERLAND, OH—April 19, 2016
With a flexible data rate over previous CAN limits, the CAN-FD network protocol provides faster and more reliable data transmission in automotive networks. Larger data payloads improve the CAN protocol’s efficiency and result in a higher communications throughput. Already widely in use in Germany, CAN-FD is commonly used in automotive applications such as OEM, system design and in real-time ECU simulation.
At…
T&D A/C Adapters Comply with New EPA Regulations
Japan’s #1 Temperature Datalogger Manufacturer
CHESTERLAND, OH—April 18, 2016
Effective last month, the EPA has enacted a new efficiency regulation concerning wall transformers. In order to comply with this regulation, TandD has changed all of their A/C Adapter model numbers. To help ease this transition, TandD has published a chart showing their current model numbers and the new model numbers for the A/C Adapters. You can find the chart here: http://www.tandd.com/support/other/other_acadapter.html. At…